MODEL DG940
MODEL NUMBER |
PH | HZ | VOLTAGE | RATED kW | MAX AMPS | * MAX. PRES INCHES W.C. |
* MAX VAC INCHES W.C. |
MAX FLOW CFM | WT. LBS | NOISE LEVEL dBA |
---|---|---|---|---|---|---|---|---|---|---|
DG940-26 |
3 |
50 |
200-240/345-415 |
13 |
46.8/27 |
40 |
52 |
1267 |
407 |
75 |
DG940-27 |
3 |
60 |
575 |
15 |
19 |
27 |
40 |
1522 |
407 |
84 |
DG940-36 |
3 |
50 |
200-240/345-415 |
20 |
66.7/38.6 |
64 |
80 |
1267 |
458 |
75 |
DG940-37 |
3
|
60
|
575
|
22
|
28
|
64
|
76
|
1522 |
458
|
84
|
DG940-46 |
3
3 |
50
60 |
200-240/345-415
220-275/380-480 |
25
29 |
88.5/51
92/53.2 |
104
88 |
120
108 |
1267 |
495
495 |
75
84 |
DG940-47 |
3 |
60 |
575 |
29 |
39 |
88 |
108 |
1522 |
495 |
84 |
*Maximum operating pressure and vaccum levels are based on optimum supply voltage. Low (or high) voltage supply may reduce the achievable pressure/vacuum levels while remaining within nameplate amperage limitations.