MODEL DG400

CONSTRUCTION FEATURES

  • Fine grain cast aluminum impeller and casings for maximum heat dissipation
  • C-UL-US registered for service in Canada and the USA
  • IP-55 rated (TEFC) motors
  • Mountable in either horizontal or vertical positions
  • Inlet and outlet silencers for quiet operation
  • 2” F. NPT connection size

ELECTRICAL SPECIFICATIONS AND CAPACITIES

MODEL
NUMBER
PH HZ VOLTAGE RATED kW MAX AMPS * MAX. PRES
INCHES W.C.
* MAX VAC
INCHES W.C.
MAX FLOW CFM WT. LBS NOISE LEVEL
dBA
DG400-21
1
1
50
60
100-120/200-240
110-120/220-240
1.1
1.3
17/8.5
19/9.6
60
56
60
60
130
155
51.7
70
73
DG400-31
1
50
60
100-120/200-240
110-120/220-240
1.5
1.75
20/10
22.8/11.4
76
68
72
72
130
155
57.2
70
73
DG400-26
3
3
50
60
200-240/345-415
220-275/380-480
.9
1.1
4.2/2.4
4.5/2.6
72
64
72
68
130
155
48.4
70
73
DG400-27
3
60
575
1.1
1.8
64
68
155
48.4
73
DG400-36
3
50
60
200-240/345-415
220-275/380-480
1.75
1.9
6.7/3.9
7/4
88
80
84
80
130
155
50.6
70
73
DG400-37
3
60
575
1.9
3.1
80
80
155
50.6
73
DG400-46
3
50
200-240/345-415
220-275/380-480
2.2
7.8/4.5
9.5/5.5
108
116
88
102
130
155
57.2
70
73
DG400-47
3
60
575
2.6
3.6
116
102
155
57.2
73

*Maximum operating pressure and vacuum levels are based on optimum supply voltage. Low (or high) voltage supply may reduce the achievable pressure/vacuum levels while remaining within nameplate amperage limitations.