MODEL DG330
MODEL NUMBER |
PH | HZ | VOLTAGE | RATED kW | MAX AMPS | * MAX. PRES INCHES W.C. |
* MAX VAC INCHES W.C. |
MAX FLOW CFM | WT. LBS | NOISE LEVEL dBA |
---|---|---|---|---|---|---|---|---|---|---|
DG330-11TS |
1 |
50 |
100-120/200-240 |
1.5 |
20/10 |
100 |
96 |
92 |
63 |
66 |
DG330-16TS |
3 |
50 |
200-240/345-415 |
1.75 |
6.7/3.9 |
120 |
110 |
92 |
55 |
66 |
DG330-17TS |
3 |
60 |
575 |
1.9 |
3.1 |
120 |
110 |
110 |
55 |
69 |
DG330-26TS |
3
|
50
60 |
200-240/345-415
220-275/380-480 |
2.2
2.6 |
7.8/4.5
9.5/5.5 |
156
168 |
128
140 |
92 |
62
|
66
69 |
DG330-27TS |
3
|
60
|
575
|
2.6
|
3.6
|
168
|
140
|
110 |
62
|
69
|
*Maximum operating pressure and vacuum levels are based on optimum supply voltage. Low (or high) voltage supply may reduce the achievable pressure/vacuum levels while remaining within nameplate amperage limitations.
NOTE: "TS" suffix in the model numbers designates a winding embedded thermistor switch is included for pilot duty service for protection of the blower from over-temperature. This is added protection, and motor overload protection is still required in the magnetic motor starter or VFD.